Belanger interface with WashMax OverviewThe Belanger Vector and FreeStyler car wash models offer limited capability to report faults to WashMax.Older WashMax site controller models may connect directly to a Belanger controller via an RS-232 cable. This is out of favor due to limitations however. The favored hardware configuration involves connecting a serial device server, such as a Moxa nPort, to the Belanger controller and to the site's Ethernet network or a Site Server's Auxiliary Connection #2. Hardware connectionsMount the Moxa nPort near the Belanger controller and connect it to the site's Ethernet network. Use a standard serial cable to connect to Moxa to port ??? on the Belanger controller. Depending on the Belanger controller model, a null-modem adapter may be needed:
Serial Device Server configurationWhen using a device server, it must be configured as:
Edge SettingsThe edge should find the Moxa if it's at one of the normal IP addresses for a Belanger Moxa. (As specified above.) If something else is used, you must edit /home/intelio/conf/site.properties and set belanger.ip.host to the IP address. The edge app must be restarted for it to take effect.Link: |