AUTEC car wash interface
Use Activa Direct Arming for AUTEC car washes.
Activa Direct Settings
In Activa Direct:
- Set "Out-Of-Service when" to "Busy Signal Blink or Power Off"
- Set "Time to hold Arming Signal" to "5 mins" (recommended). As little as "2 secs" will work.
- Set "Time to wait for wash to begin" to "5 mins"
Interface Wiring
The AUTEC PLC can only receive one output signal at a time to select a wash package. To handle combination washes on the EV-1 (combination system), a signal decoder is needed. The table below simply shows a basic wiring example.
-
Interface Name
|
Activa Terminal
|
AUTEC Terminal |
Arming Output 2
|
712
|
Package 1 - Terminal 10
|
Arming Output 3
|
713
|
Package 2 - Terminal 11
|
Arming Output 4
|
714
|
Package 3 - Terminal 12
|
Arming Output 5
|
715
|
Package 4 - Terminal 33
|
Arming Output 6
|
716
|
Package 5 - Terminal 34
|
Arming Output 7
|
717
|
Package 6 - Terminal 35
|
Arming Output 8
|
718
|
Package 7 - Terminal 36
|
|
|
Package 8 - Terminal 37
|
Arming Output Common
|
719
|
DC-
|
Busy/Wash-in-Use Input
|
720
|
Terminal 230 (2nd PLC, 3L.0 terminal)
|
Control Power Input
|
721
|
DC+
|
Input Common
|
722
|
DC-
|
Link:
|