Approved Wire and Uses

Print
Save to list
E-mail
Subscribe

Ethernet (Internet) Wire

Run one Ethernet cable from the network access point (modem, router, switch...etc) to each Activa Virtual Attendant and to the Activa Site Controller.

Use shielded, Stranded CAT5e, any quality brand.

Activa Direct Wire

Activa Direct wire is used between the Activa Virtual Attendant terminals and the car wash PLC.

Use 18 gage shielded, stranded 10 conductor.

Echelon (RykoNet) Wire

Echelon wire is only used at sites with a Ryko car wash. It runs between each car wash PLC and its associated Activa Virtual Attendant, and then front either of those to the Site Controller.

Echelon wire is 18 gauge twisted pair. Only the following are approved for use:
  • Belden 8760 (top choice)
  • Belden 9318
  • Belden 88760
  • Carol C2521
  • Carol C2534
  • Alpha 2421C
  • Manhattan 13242
Run wire to each Echelon device, and tie them together in one place using a terminal block or (for just a few wires) two wire caps.




Related Articles
How to reprogram an Activa Bill Acceptor
This procedure describes how to reprogram an Activa bill acceptor. It assumes that the FP-001 Programmer device has already been loaded with the desired firmware program to...
How to setup RykoNet over IP
Introduction The Activa Virtual Attendant and Site Controller communicate with each other over over a protocol known as RykoNet. This software protocol can be physically...
Activa Direct Wash Arming
Use Activa Direct arming to control the car wash through a direct wired connection to the Activa's I/O terminals. To Select Activa Direct: Log into the...
Powered by KnowledgeBuilder