Nu-Star interface with WashMax

Print
Save to list
E-mail
Subscribe

Overview

The Nu-Star Comet II model can report a few faults to WashMax via simple relays.

Hardware

The hardware needed is a  Kit 108 I/O Relay Board connected to a Serial Device Server such as the Moxa NPort. These can be mounted in an Activa base along with a network switch.  A diagram at the end of this article shows how to wire the I/O relay board to the Nu-Star PLC.

Serial Device Server configuration

When using a device server (ex: Moxa nPort), it must be configured as:
  • Run as a TCP Server listening on port 4001.
  • Serial side set to 9600 baud, 8 bit data, 1 stop bit, no parity, and no flow control.



Attachments