Use ActivaDirect Arming for the Belanger Vector and FreeStyler car washes.
Activa Direct Settings
In Activa Direct:
Set "Out-Of-Service when" to "Busy Signal Blink or Power Off"
Set "Time to hold Arming Signal" to "15 mins".
Set "Time to wait for wash to begin" to "15 mins"
Interface Wiring
Interface Name
Activa Terminal
Vector
FreeStyler
Arming Output 2
712
X-20
X-18
Arming Output 3
713
X-21
X-19
Arming Output 4
714
X-22
X-20
Arming Output 5
715
X-23
X-22
Arming Output Common
719
B-338 0VDC
B-338 0VDC
Busy/Wash-in-Use Input
720
B-728
B-728
Control Power Input
721
B-340 24VDC
B-340 24VDC
Input Common
722
B-338 0VDC
B-338 0VDC