Search Results for "configuration"

Displaying 10 out of 22 found articles:
PDQ car wash interface with WashMax
This article is protected and thus no preview is available.
Relevance: 20.8   |   WashMax > Carwash Interfaces

Wash Select II interface and configuration
WashMax can work with the Unitec Wash Select II teller. The Wash Select II and POS 4000 manuals are attached to the end of this article. Hardware Interface Configuration a Moxa: For a Moxa nPort 5110, use a null-modem adapter....
Relevance: 19.25   |   WashMax > Teller Interfaces

Custom TG02 printer printing gibberish / wrong baud rate
The Custom TG02 printer can be configured by powering it on while holding both the FEED and REPORT buttons. To do this, login to the Activa, and touch Diagnostics and then Sensors/Relays . Then touch the Outputs/Relays tab. Touch...
Relevance: 17.71   |   Activa > Troubleshooting

AUTEC interface with WashMax
The WashMax site controller connects with an AUTEC car wash PLC via an adapter called a PPI MultiMaster. This adapter converts the RS-485 signals used by the car wash's PLCs to RS-232. The RS-232 end may be connected directly to an...
Relevance: 16.52   |   WashMax > Carwash Interfaces

Site Server Flash Imager
The sserv8 Flash Imager drive may be used to initialize a Site Server, Site Controller, or Ryko Code-a-Wash hardware with all of the current software needed for PCI DSS and PA-DSS compliant use of WashMax services. Initialization...
Relevance: 12.47   |   Site Server > Software Installation

Belanger interface with WashMax
Overview The Belanger Vector and FreeStyler car wash models offer limited capability to report faults to WashMax. Older WashMax site controller models may connect directly to a Belanger controller via an RS-232 cable. This is out of...
Relevance: 12.45   |   WashMax > Carwash Interfaces

Code-a-Wash Reports show incorrect change
The Code-a-Wash application has settings indicating the monetary denomination of change given by the Activa. These values must match the Activa configuration, otherwise reports will be incorrect. Login to the Code-a-Wash...
Relevance: 11.32   |   Site Server > Troubleshooting

Nu-Star interface with WashMax
Overview The Nu-Star Comet II model can report a few faults to WashMax via simple relays. Hardware The hardware needed is a  Kit 108 I/O Relay Board connected to a Serial Device Server such as the Moxa NPort . These can...
Relevance: 10.49   |   WashMax > Carwash Interfaces

How to configure a new Site Server (sserv) for latest
This article is protected and thus no preview is available.
Relevance: 8.74   |   Site Server > Software Installation

How to configure a new Site Server (sserv) for Cobra
This article is protected and thus no preview is available.
Relevance: 8.36   |   Site Server > Software Installation