PDQ car wash interface with WashMax
|
This article is protected and thus no preview is available.
Relevance: 20.8 | WashMax > Carwash Interfaces
|
|
Wash Select II interface and configuration
|
WashMax can work with the Unitec Wash Select II teller. The Wash Select II and POS 4000 manuals are attached to the end of this article.
Hardware Interface
Configuration a Moxa:
For a Moxa nPort 5110, use a null-modem adapter....
Relevance: 19.25 | WashMax > Teller Interfaces
|
|
Custom TG02 printer printing gibberish / wrong baud rate
|
The Custom TG02 printer can be configured by powering it on while holding both the FEED and REPORT buttons. To do this, login to the Activa, and touch Diagnostics and then Sensors/Relays . Then touch the Outputs/Relays tab. Touch...
Relevance: 17.71 | Activa > Troubleshooting
|
|
AUTEC interface with WashMax
|
The WashMax site controller connects with an AUTEC car wash PLC via an adapter called a PPI MultiMaster. This adapter converts the RS-485 signals used by the car wash's PLCs to RS-232. The RS-232 end may be connected directly to an...
Relevance: 16.52 | WashMax > Carwash Interfaces
|
|
Site Server Flash Imager
|
The sserv8 Flash Imager drive may be used to initialize a Site Server, Site Controller, or Ryko Code-a-Wash hardware with all of the current software needed for PCI DSS and PA-DSS compliant use of WashMax services. Initialization...
Relevance: 12.47 | Site Server > Software Installation
|
|
Belanger interface with WashMax
|
Overview
The Belanger Vector and FreeStyler car wash models offer limited capability to report faults to WashMax. Older WashMax site controller models may connect directly to a Belanger controller via an RS-232 cable. This is out of...
Relevance: 12.45 | WashMax > Carwash Interfaces
|
|
Code-a-Wash Reports show incorrect change
|
The Code-a-Wash application has settings indicating the monetary denomination of change given by the Activa. These values must match the Activa configuration, otherwise reports will be incorrect.
Login to the Code-a-Wash...
Relevance: 11.32 | Site Server > Troubleshooting
|
|
Nu-Star interface with WashMax
|
Overview
The Nu-Star Comet II model can report a few faults to WashMax via simple relays.
Hardware
The hardware needed is a Kit 108 I/O Relay Board connected to a Serial Device Server such as the Moxa NPort . These can...
Relevance: 10.49 | WashMax > Carwash Interfaces
|
|
How to configure a new Site Server (sserv) for latest
|
This article is protected and thus no preview is available.
Relevance: 8.74 | Site Server > Software Installation
|
|
How to configure a new Site Server (sserv) for Cobra
|
This article is protected and thus no preview is available.
Relevance: 8.36 | Site Server > Software Installation
|