Use Activa Direct Arming for the Mark VII CombiWash.

PLC Settings

Minimum firmware 3.28.

On the PLC:
  • set module 60 (Entry System), parameter 13 to 002 - Wash in use - Extended - Unitec
  • set module 70 (Special Function Menu), parameter 9 to 104 - Off when fault.

Activa Direct Settings

In Activa Direct:
  • Set "Out-Of-Service when" to "Busy Signal Blink or Power Off"
  • Set "Time to hold Arming Signal" to "15 minutes".
  • Set "Time to wait for wash to begin" to "15 minutes"